Axial-flexural capacity of short column

The calculation below provides the bending capacity (PM) of a rectangular short column


Input:

psi
ksi
in
in

tip: You can drag the verts to different spots. Changing 'nb' will reset it.

Output:

    Definitions
    • ϕc = Resistance factor for concrete
    • ϕs = Resistance factor for reinforcing steel
    • fc = Specified concrete strength (psi)
    • fy = Specified reinforcing steel yield strength (ksi)
    • b = Effective width of cross section (in)
    • h = Overall depth of cross section (in)
    • nb = Quantity of reinforcing bars
    Properties
    • Gross Area: 144 in²
    • Steel Area: 4.65 in²
    • Concrete Area: 139.4 in²
    • Reinforcing Ratio: 0.0323
    • Ix: 1728 in⁴
    • Iy: 1728 in⁴
    • Pmin: -480 kip
    • Pmax: 237 kip
    User Notes: